A customer of SINRUI Mining in Indonesia experienced severe radiator aging on their CAT D8R bulldozers.

The original aluminum AMOCS-type radiators used modular cores sealed with rubber gaskets. Over time, the seals deteriorated under constant heat and vibration. As the gaskets failed, coolant began to leak. Several aluminum modules loosened and corrod...

A customer of SINRUI Mining in Indonesia experienced severe radiator aging on their CAT D8R bulldozers.

The original aluminum AMOCS-type radiators used modular cores sealed with rubber gaskets. Over time, the seals deteriorated under constant heat and vibration.

AMOCS Radiator Structure in D8R Bulldozer.jpg

As the gaskets failed, coolant began to leak. Several aluminum modules loosened and corroded, reducing cooling efficiency and causing frequent downtime.

AMOCS Radiator Structure in D8R Bulldozer.jpg

To address these issues, SINRUI Mining supplied copper fin-tube radiators to replace the AMOCS structure.

The copper design offers better heat transfer, stronger resistance to oxidation and vibration, and a longer service life.

After installation, the upgraded radiators delivered stable cooling performance and extended maintenance intervals—providing a durable, low-maintenance solution for continuous mining operations.

Sinrui Mining Replaceable Copper Fin Heatsink Running on CAT D8R.jpg

Prev

Copper Core Retrofit Solution

All applications Next

A mining operator in South Africa experienced recurring cooling issues with the aluminum radiators used on their CAT 390 excavators.

865368590148

+86-15684211561

[email protected]

Get a Free Quote

Our representative will contact you soon.
Name
Email
Mobile
Company Name
Message
0/1000